AMX Multiple Products Credential Management Vulnerabilities (Update A)
OVERVIEW
This updated advisory is a follow-up to the original advisory titled ICSA-16-049-02 AMX Multiple Products Credential Management Vulnerabilities that was published February 18, 2016, on the NCCIC/ICS-CERT web site.
--------- Begin Update A Part 1 of 2 --------
ICS-CERT has become aware of public reporting of credential management vulnerabilities in multiple AMX multimedia devices. AMX has confirmed the existence of hard-coded passwords in multiple products. AMX has produced patches and new product versions to mitigate the vulnerabilities in the affected products. AMX has released new product versions to mitigate the remaining credential management vulnerability in their affected products.
--------- End Update A Part 1 of 2 ----------
These vulnerabilities could be exploited remotely. Exploits that target these vulnerabilities are known to be publicly available.
AFFECTED PRODUCTS
The following AMX multimedia devices are affected by vulnerability CVE-2015-8362:
- NX-1200, NX-2200, NX-3200, NX-4200 NetLinx Controller, versions prior to Version 1.4.65,
- Massio ControlPads MCP-10x, versions prior to Version 1.4.65,
- Enova DVX-x2xx, versions prior to Version 1.4.65,
- DVX-31xxHD-SP (-T), versions prior Version 4.8.331,
- DVX-21xxHD-SP (-T), versions prior Version 4.8.331,
- DVX-2100HD-SP-T Master, versions prior to Version 4.1.420 (Hotfix firmware version),
- Enova DGX 100 NX Series Master, versions prior to Version 1.4.72 (Hotfix firmware version),
- Enova DGX 8/16/32/64 NX Series Master, versions prior to Version 1.4.72 (Hotfix firmware version),
- Enova DGX 8/16/32/64 NI Series Master, versions prior to Version 4.2.397 (Hotfix firmware version),
- NI-700, NI-900 Master Controllers (64M RAM), versions prior to Version 4.1.419,
- NI-700, NI-900 Master Controllers (32M RAM), versions prior to Version 3.60.456 (Hotfix firmware version),
- NI-2100, NI-3100, NI-4100, NI-2100 with ICSNet, NI-3100 with ICSNet, NI-3100/256,
NI-3100/256 with ICSNet, NI-4100/256, versions prior to Version 4.1.419, - NI-3101-SIG Master Controller, versions prior to Version 4.1.419,
- NI-2000, NI-3000, NI-4000, versions prior to Version 3.60.456 (Hotfix firmware version), and
- ME260/64 Duet, versions prior to Version 3.60.456 (Hotfix firmware version).
The following AMX multimedia devices are affected by vulnerability CVE-2016-1984:
- NX-1200, NX-2200, NX-3200, NX-4200 NetLinx Controller, Version 1.4.65 and Version 1.4.66 (Hotfix firmware version),
- Massio ControlPads MCP-10x, Version 1.4.65 and Version 1.4.66 (Hotfix firmware version),
- Enova DVX-x2xx, Version 1.4.65 and Version 1.4.72 (Hotfix firmware version),
- Enova DGX 100 NX Series Master, Version 1.4.72 (Hotfix firmware version), and
- Enova DGX 8/16/32/64 NX Series Master, Version 1.4.72 (Hotfix firmware version).
IMPACT
Successful exploitation of these vulnerabilities may allow an attacker to remotely gain access to the affected systems with elevated privileges to configure user interfaces, change device settings, upload files, and download files.
Impact to individual organizations depends on many factors that are unique to each organization. ICS-CERT recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation.
BACKGROUND
AMX is part of the Harman Professional Division, which provides audio and video solutions for IT environments. AMX is a US-based company that is headquartered in Dallas, Texas.
The affected products are used for audio and video automation in conference rooms and classrooms. According to AMX, these products are deployed across the Commercial Facilities and Government Facilities sectors. AMX estimates that these products are used worldwide.
VULNERABILITY CHARACTERIZATION
VULNERABILITY OVERVIEW
CREDENTIALS MANAGEMENTCWE-255: Credentials Management, http://cwe.mitre.org/data/definitions/255.html, web site last accessed February 18, 2016.
Affected devices contain a hard-coded password for a diagnostic account with elevated privileges that can be used to configure user settings, device settings, upload files, and download files.
CVE-2015-8362NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2015-8362, This web site was last accessed February 18, 2016. has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been assigned by AMX; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:H).CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:H, web site last accessed February 18, 2016.
CREDENTIALS MANAGEMENTCWE-255: Credentials Management, http://cwe.mitre.org/data/definitions/255.html, web site last accessed February 18, 2016.
Affected devices contain a hard-coded password for an account that has privileges to exchange Internet Control System Protocol (ICSP) messages, which are accessed via Port 1319/TCP and UDP. AMX reports that this hard-coded password affects firmware Version 1.4.x.
CVE-2016-1984NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-1984, This web site was last accessed February 18, 2016. has been assigned to this vulnerability. A CVSS v3 base score of 5.8 has been assigned by AMX; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N). CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N, web site last accessed February 18, 2016.
VULNERABILITY DETAILS
EXPLOITABILITY
These vulnerabilities could be exploited remotely.
EXISTENCE OF EXPLOIT
Exploits that target these vulnerabilities are known to be publicly available.
DIFFICULTY
An attacker with a low skill would be able to exploit these vulnerabilities.
MITIGATION
AMX has reported the release of standard firmware versions and Hotfix firmware versions, which mitigates vulnerability, CVE-2015-8362, in the affected products. AMX’s standard firmware releases for affected products are available for download at the following URL, with a valid account:
http://www.amx.com/techcenter/.
AMX’s Hotfix firmware versions are intended to mitigate vulnerability, CVE-2015-8362, until standard firmware versions are available. AMX’s Hotfix firmware versions are available through AMX Tech Support. AMX Tech Support may be reached at (US) 800-932-6993, (International) +1-469-624-8000 or by email at:
AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.
--------- Begin Update A Part 2 of 2 --------
The credential management vulnerability, CVE-2016-1984, affects firmware Versions 1.4.65 through 1.4.72. AMX has released firmware to mitigate these vulnerabilities. The following software versions should be applied to mitigate the credential management vulnerability:
- AMX Enova DVX Product Line:
- Master 1.5.68 (or newer)
- Switcher 1.7.54 (or newer)
- AMX Enova DGX Product Line:
- Master 1.5.68 (or newer)
- Switcher 3.2.19 (or newer)
AMX’s standard firmware releases for affected products are available for download at the following URL, with a valid account:
http://www.amx.com/techcenter/.
--------- End Update A Part 2 of 2 ----------
ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
This product is provided subject to this Notification and this Privacy & Use policy.
Vendor
- Harman