ICS Advisory

GAIN Electronic Co. Ltd SAGA1-L Series

Last Revised
Alert Code
ICSA-18-296-02

1. EXECUTIVE SUMMARY

  • CVSS v3 8.3
  • ATTENTION: Exploitable from an adjacent network/low skill level to exploit
  • Vendor: GAIN Electronic Co. Ltd
  • Equipment: SAGA1-L series 
  • Vulnerabilities: Authentication Bypass by Capture-replay, Improper Access Control, Improper Authentication

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow remote code execution and potentially delete the product’s firmware.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

According to GAIN Electronic Co. Ltd, the following product is affected:

  • SAGA1-L8B: All firmware versions prior to A0.10

3.2 VULNERABILITY OVERVIEW

3.2.1    AUTHENTICATION BYPASS BY CAPTURE-REPLAY CWE-294

This product is vulnerable to a replay attack and command forgery.

CVE-2018-17903 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H).

3.2.2    IMPROPER ACCESS CONTROL CWE-284

This vulnerability may allow an attacker to force-pair the device without human interaction.

CVE-2018-17921 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.3    IMPROPER AUTHENTICATION CWE-287

An attacker with physical access to the product may able to reprogram it.

CVE-2018-17923 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Communications
  • COUNTRIES/AREAS DEPLOYED: United States 
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

Marco Balduzzi, Philippe Z Lin, Federico Maggi, Jonathan Andersson, Urano Akira, Stephen Hilt, and Rainer Vosseler working with Trend Micro’s Zero Day Initiative reported these vulnerabilities to NCCIC.

4. MITIGATIONS

GAIN Electronic Co. Ltd has recommended that users update to firmware version A0.10. The new firmware can be obtained through a distributor.

NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should ensure the product is in a physically secure area.

NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.

No known public exploits specifically target these vulnerabilities.

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor

  • GAIN Electronic Co. Ltd