ICS Advisory

EZAutomation EZ Touch Editor

Last Revised
Alert Code
ICSA-19-246-01

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Low skill level to exploit
  • Vendor: EZAutomation
  • Equipment: EZ Touch Editor
  • Vulnerability: Stack-based Buffer Overflow

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to execute code under the privileges of the application.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of EZ Touch Editor, a Human-Machine Interface Editor, are affected:

  • EZ Touch Editor Versions 2.1.0 and prior

3.2 VULNERABILITY OVERVIEW

3.2.1    STACK-BASED BUFFER OVERFLOW CWE-121

An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application. 

CVE-2019-13518 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Multiple 
  • COUNTRIES/AREAS DEPLOYED: Worldwide 
  • COMPANY HEADQUARTERS LOCATION: United States 

3.4 RESEARCHER

9sg Security Team, working with Trend Micro’s Zero Day Initiative, reported this vulnerability to CISA.

4. MITIGATIONS

EZAutomation recommends users update to Version 2.2.0 or later.

EZAutomation recommends the following workaround to further reduce risk:

  • Use project files from known sources.

CISA also recommends users take the following measures to protect themselves from social engineering attacks: 

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.



Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. 

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor

  • EZAutomation