ICS Advisory

Delta Electronics TPEditor

Last Revised
Alert Code
ICSA-21-021-02

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Low skill level to exploit
  • Vendor: Delta Electronics (Delta)
  • Equipment: TPEditor
  • Vulnerabilities: Untrusted Pointer Dereference, Out-of-bounds Write

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute code under the privileges of the application.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of TPEditor, programming software for Delta text panels, are affected:

  • TPEditor: v1.98 and prior

3.2 VULNERABILITY OVERVIEW

3.2.1    UNTRUSTED POINTER DEREFERENCE CWE-822

An untrusted pointer dereference has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution. 

CVE-2020-27288 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

 3.2.2    OUT-OF-BOUNDS WRITE CWE-787

The affected product is vulnerable to two out-of-bounds write instances in the way it processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution. 

CVE-2020-27284 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

kimiya, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA.

4. MITIGATIONS

Delta recommends updating to v1.98.03 or later.

CISA recommends users take the following measures to protect themselves from social engineering attacks:

be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.



CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.



Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor

  • Delta Electronics