Geutebrück G-Cam E2 and G-Code
1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity/public exploits are available
- Vendor: Geutebrück
- Equipment: G-Cam E2 and G-Code
- Vulnerabilities: Missing Authentication for Critical Function, Command Injection, Stack-based Buffer Overflow
2. RISK EVALUATION
UDP Technology supplies multiple OEMs such as Geutebrück with firmware for IP cameras. Successful exploitation of these vulnerabilities could allow unauthenticated access to sensitive information; buffer overflow and command injection conditions may allow remote code execution.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following Geutebrück devices contain the affected third-party firmware provided by UDP Technology:
- E2 Series cameras – G-CAM; Versions 1.12.0.27 and prior, Versions 1.12.13.2 and 1.12.14.5
- EBC-21xx
- EFD-22xx
- ETHC-22xx
- EWPC-22xx
- Encoder G-Code; Versions 1.12.0.27 and prior, Versions 1.12.13.2 and 1.12.14.5
- EEC-2xx
- EEN-20xx
3.2 VULNERABILITY OVERVIEW
3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306
The affected product allows unauthenticated remote access to sensitive files due to default user authentication settings.
CVE-2021-33543 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77
The affected product is vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33544 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.3 STACK-BASED BUFFER OVERFLOW CWE-121
The affected product is vulnerable to a stack-based buffer overflow condition in the counter parameter which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33545 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.4 STACK-BASED BUFFER OVERFLOW CWE-121
The affected product is vulnerable to a stack-based buffer overflow condition in the name parameter, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33546 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.5 STACK-BASED BUFFER OVERFLOW CWE-121
The affected product is vulnerable to a stack-based buffer overflow condition in the profile parameter which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33547 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.6 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77
The affected product is vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33548 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.7 STACK-BASED BUFFER OVERFLOW CWE-121
The affected product is vulnerable to a stack-based buffer overflow condition in the action parameter, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33549 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.8 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77
The affected product is vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33550 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.9 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77
The affected product is vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33551 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.10 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77
The affected product is vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33552 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.11 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77
The affected product is vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33553 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.2.12 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77
The affected product is vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-33554 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Energy, Financial Services, Government Facilities, Healthcare and Public Health, Transportation Systems
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER
Titouan Lazard and Ibrahim Ayadhi from RandoriSec reported these vulnerabilities to CISA.
4. MITIGATIONS
Geutebrück strongly recommends updating all affected cameras and encoders listed above to firmware Version 1.12.14.7 or later. The security advisory and the latest firmware can both be acquired on Geutebrück’s web portal (Login required).
If updates cannot be deployed, Geutebrück recommends taking the following defensive measures to minimize the risk of exploitation of these vulnerabilities:
- Change the default passwords of the cameras.
- Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls and isolate them from the business network.
- When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
- Ultimately shut down or disconnect the cameras from the network.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
This product is provided subject to this Notification and this Privacy & Use policy.
Vendor
- Geutebrück