ICS Advisory

Open Design Alliance Drawing SDK

Release Date
Alert Code
ICSA-23-353-04

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Low attack complexity
  • Vendor: Open Design Alliance (ODA)
  • Equipment: Drawing SDK
  • Vulnerabilities: Use after Free, Heap-based Buffer Overflow

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow remote attackers to disclose sensitive information on affected installations of ODA Drawing SDK.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of ODA Drawing SDK are affected:

  • Drawing SDK: Versions prior to 2024.1

3.2 Vulnerability Overview

3.2.1 USE AFTER FREE CWE-416

Open Design Alliance's Drawing SDK prior to Version 2024.1 is vulnerable to a use after free attack. Exploitation of this vulnerability requires the target to visit a malicious page or open a malicious file. The specific vulnerability exists within the parsing of DWG files. Crafted data in a DWG file can trigger a use after free attack past the end of an allocated buffer. An attacker could leverage this vulnerability in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process.

CVE-2023-26495 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C).

3.2.2 HEAP-BASED BUFFER OVERFLOW CWE-122

Parsing of DWG files in Open Design Alliance Drawings SDK before 2023.6 lacks proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2023-22669 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C).

3.2.3 HEAP-BASED BUFFER OVERFLOW CWE-122

A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVE-2023-22670 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Multiple
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Mat Powell and Jimmy Calderon of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.

4. MITIGATIONS

Please see ODA security advisory 24.1 and 23.6 for more information.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.

5. UPDATE HISTORY

  • December 19, 2023: Initial Publication

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor