RAD Data Communications SecFlow-2
1. EXECUTIVE SUMMARY
- CVSS v4 8.7
- ATTENTION: Exploitable remotely/low attack complexity/public exploits are available
- Vendor: RAD Data Communications
- Equipment: SecFlow-2
- Vulnerability: Path Traversal
2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to obtain files from the operating system by crafting a special request.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following RAD Data Communications products are affected:
- SecFlow-2: All versions
3.2 Vulnerability Overview
3.2.1 PATH TRAVERSAL: '..\FILENAME' CWE-29
RAD SecFlow-2 devices with Hardware 0202, Firmware 4.1.01.63, and U-Boot 2010.12 allow URIs beginning with /.. for Directory Traversal, as demonstrated by reading /etc/shadow.
CVE-2019-6268 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A CVSS v4 score has also been calculated for CVE-2019-6268. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Communications
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Israel
3.4 RESEARCHER
CISA discovered a PoC (Proof of Concept) and reported it to RAD Data Communications.
4. MITIGATIONS
RAD Data Communications reports that SecFlow-2 is EOL (End-Of-Life) and recommends upgrading to the more secure RAD SecFlow-1p product line.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY
- June 18, 2024: Initial Publication
This product is provided subject to this Notification and this Privacy & Use policy.