National Instruments LabVIEW
1. EXECUTIVE SUMMARY
- CVSS v4 7.1
- ATTENTION: Low attack complexity
- Vendor: National Instruments
- Equipment: LabVIEW
- Vulnerabilities: Out-of-bounds Write
2. RISK EVALUATION
Successful exploitation of these vulnerabilities lead to the execution of arbitrary code on affected installations of LabVIEW, which could result in invalid memory writes.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of LabVIEW are affected:
- LabVIEW: 2025 Q1 and prior versions
3.2 VULNERABILITY OVERVIEW
3.2.1 OUT-OF-BOUNDS WRITE CWE-787
LabVIEW 2025 Q1 and prior versions are vulnerable to an out-of-bounds write when parsing user-supplied data, which may allow an attacker to remotely execute arbitrary code.
CVE-2025-2631 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-2631. A base score of 7.1 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.2 OUT-OF-BOUNDS WRITE CWE-787
LabVIEW 2025 Q1 and prior versions are vulnerable to an out-of-bounds write when parsing user-supplied data, which may allow an attacker to remotely execute arbitrary code.
CVE-2025-2632 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-2632. A base score of 7.1 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER
Michael Heinzl reported these vulnerabilities to CISA.
4. MITIGATIONS
National Instruments has released the following patches for the affected products:
- For those affected by CVE-2025-2631 click here.
- For those affected by CVE-2025-2632 click here.
Please refer to the vendor's advisory for further information.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open attachments in unsolicited email messages.
- Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
- Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.
5. UPDATE HISTORY
- April 15, 2025: Initial Publication
This product is provided subject to this Notification and this Privacy & Use policy.
Vendor
- National Instruments