ICS Advisory

Planet Technology Network Products

Release Date
Alert Code
ICSA-25-114-06

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 9.3
  • ATTENTION: Exploitable remotely/Low attack complexity
  • Vendor: Planet Technology
  • Equipment: Planet Technology Network Products
  • Vulnerabilities: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Use of Hard-coded Credentials, Missing Authentication for Critical Function

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to read or manipulate device data, gain administrative privileges, or alter database entries.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Planet Technology products are affected:

  • UNI-NMS-Lite: Versions 1.0b211018 and prior
  • NMS-500: All Versions
  • NMS-1000V: All Versions
  • WGS-804HPT-V2: Versions 2.305b250121 and prior
  • WGS-4215-8T2S: Versions 1.305b241115 and prior

3.2 VULNERABILITY OVERVIEW

3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND ('OS COMMAND INJECTION') CWE-78

UNI-NMS-Lite is vulnerable to a command injection attack that could allow an unauthenticated attacker to read or manipulate device data.

CVE-2025-46271 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N).

A CVSS v4 score has also been calculated for CVE-2025-46271. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N).

3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND ('OS COMMAND INJECTION') CWE-78

WGS-80HPT-V2 and WGS-4215-8T2S are vulnerable to a command injection attack that could allow an unauthenticated attacker to execute OS commands on the host system.

CVE-2025-46272 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N).

A CVSS v4 score has also been calculated for CVE-2025-46272. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N).

3.2.3 USE OF HARD-CODED CREDENTIALS CWE-798

UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to gain administrative privileges to all UNI-NMS managed devices.

CVE-2025-46273 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-46273. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.4 USE OF HARD-CODED CREDENTIALS CWE-798

UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to read, manipulate and create entries in the managed database.

CVE-2025-46274 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-46274. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.5 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306

WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could allow an attacker to create an administrator account without knowing any existing credentials.

CVE-2025-46275 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-46275. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

Kev Breen of Immersive reported these vulnerabilities to CISA.

4. MITIGATIONS

Planet Technology has released patches for the following devices:

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 24, 2025: Initial Publication

This product is provided subject to this Notification and this Privacy & Use policy.