ICS Advisory

Siemens SIMATIC, SINAMICS, SINEC, SINEMA, SINUMERIK (Update K)

Last Revised
Alert Code
ICSA-20-161-04

1. EXECUTIVE SUMMARY

--------- Begin Update K Part 1 of 2 ---------

  • CVSS v3 8.8

--------- End Update K Part 1 of 2 ---------

  • ATTENTION: Low attack complexity
  • Vendor: Siemens
  • Equipment: SIMATIC, SINAMICS, SINEC, SINEMA, SINUMERIK
  • Vulnerability: Unquoted Search Path or Element

2. UPDATE INFORMATION

This updated advisory is a follow-up to the advisory update titled ICSA-20-161-04 Siemens SIMATIC, SINAMICS, SINEC, SINEMA, SINUMERIK (Update J) that was published April 14, 2022, to the ICS webpage on www.cisa.gov/ics.

3. RISK EVALUATION

Successful exploitation of this vulnerability could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges.

4. TECHNICAL DETAILS

4.1 AFFECTED PRODUCTS

The following Siemens products are affected:

  • SIMATIC Automation Tool: All versions
  • SIMATIC NET PC software: All versions after v16 and prior to v16 Upd3
  • SIMATIC PCS neo: All versions prior to v3.0 SP1
  • SIMATIC ProSave: All versions
  • SIMATIC S7-1500 Software Controller: All versions prior to v21.8
  • SINAMICS STARTER: All versions prior to v5.4 HF2
  • SIMATIC STEP 7: All versions prior to v5.6 SP2 HF3
  • SIMATIC STEP 7 (TIA Portal) v13: All versions prior to SP2 Update 4
  • SIMATIC STEP 7 (TIA Portal) v14: All versions prior to v14 SP1 Update 10
  • SIMATIC WinCC Runtime Professional v14: All versions prior to v14 SP1 Update 10
  • SIMATIC STEP 7 (TIA Portal) v15: All versions prior to v15.1 Update 5
  • SIMATIC STEP 7 (TIA Portal) v16: All versions prior to v16 Update 2
  • SIMATIC WinCC OA v3.16: All versions prior to P018
  • SIMATIC WinCC OA v3.17: All versions prior to P003
  • SIMATIC WinCC Runtime Advanced: All versions prior to v16 Update 2
  • SIMATIC WinCC Runtime Professional v13: All versions prior to v13 SP2 Update 4
  • SIMATIC WinCC Runtime Professional v14: All versions
  • SIMATIC WinCC Runtime Professional v15: All versions prior to v15.1 Update 5
  • SIMATIC WinCC Runtime Professional v16: All versions prior to v16 Update 2
  • SIMATIC WinCC v7.4: All versions prior to v7.4 SP1 Update 14
  • SIMATIC WinCC v7.5: All versions prior to v7.5 SP1 Update 3
  • SINAMICS Startdrive: All versions
  • SINEMA Server: All versions prior to v14 SP3
  • SIMATIC ProSave: All versions prior to v17
  • SIMATIC NET PC software v14: All versions prior to v14 Update 14
  • SIMATIC NET PC software v15: All versions
  • SIMATIC NET PC software v16: All versions prior to v16 Upd3 
  • SINUMERIK ONE virtual: All versions prior to v6.14
  • SINUMERIK Operate: All versions prior to v6.14
  • SIMATIC Automation Tool: All versions prior to v4 SP2
  • SINEC NMS: All versions prior to v1.0 SP2

4.2 VULNERABILITY OVERVIEW

4.2.1    UNQUOTED SEARCH PATH OR ELEMENT CWE-428

--------- Begin Update K Part 2 of 2 ---------

The affected product is vulnerable due to a common component of the affected applications that regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local unauthorized user to execute arbitrary code with SYSTEM privileges.

CVE-2020-7580 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).

--------- End Update K Part 2 of 2 ---------

4.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Chemical, Energy, Food and Agriculture, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

4.4 RESEARCHER

Ander Martinez of Titanium Industrial Security and INCIBE reported this vulnerability to Siemens.

5. MITIGATIONS

Siemens has released updates for the following affected products and is working on further updates. For the remaining affected products, Siemens recommends specific countermeasures until fixes are available:

--------- Begin Update J Part 2 of 2 ---------

--------- End Update J Part 2 of 2 ---------

Siemens has identified the following specific workarounds and mitigations that can be applied to reduce the risk:

  • Ensure there is no executable at the following locations:
    • C:\Program.exe
    • C:\Program Files\Common.exe
    • C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
  • Deactivate the Windows service called TraceConceptX. This leads to loss of tracing functionality and should only be considered a temporary workaround.

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to the Siemens operational guidelines for Industrial Security and following the recommendations in the product manuals.

For additional information, please refer to Siemens Security Advisory SSA-312271

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.



CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

This vulnerability is not exploitable remotely. No known public exploits specifically target this vulnerability.

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor

  • Siemens