ICS Advisory

Fuji Electric Tellus Lite V-Simulator and V-Server Lite

Last Revised
Alert Code
ICSA-21-299-01

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Low attack complexity
  • Vendor: Fuji Electric
  • Equipment: Tellus Lite V-Simulator, and V-Server Lite
  • Vulnerabilities: Stack-based Buffer Overflow, Out-of-bounds Write, Untrusted Pointer Dereference, Out-of-bounds Read, Access of Uninitialized Pointer, Heap-based Buffer Overflow

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to cause data corruption, read sensitive information, obtain code execution, or crash the application.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Fuji Electric remote monitoring and operation software products are affected:

  • V-Server Lite: Versions prior to v4.0.12.0
  • Tellus Lite V-Simulator: Versions prior to v4.0.12.0

3.2 VULNERABILITY OVERVIEW

3.2.1    STACK-BASED BUFFER OVERFLOW CWE-121

The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution.

CVE-2021-38413 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.2    OUT-OF-BOUNDS WRITE CWE-787

The affected product is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution.

CVE-2021-38419 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.3    UNTRUSTED POINTER DEREFERENCE CWE-822

The affected product is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash.

CVE-2021-38401 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.4    OUT-OF-BOUNDS READ CWE-125

The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash.

CVE-2021-38421 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.5    ACCESS OF UNINITIALIZED POINTER CWE-824

The affected product is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service.

CVE-2021-38409 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.6    HEAP-BASED BUFFER OVERFLOW CWE-122

Parsing a specially crafted project file may cause a heap-based buffer overflow, which may allow an attacker to execute arbitrary code.

CVE-2021-38415  has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Japan

3.4 RESEARCHER

kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.

4. MITIGATIONS

Fuji Electric recommends updating software to the latest version:

CISA recommends users take the following measures to protect themselves from social engineering attacks:

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.



CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor

  • Fuji Electric