Siemens SIPROTEC 5
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
1. EXECUTIVE SUMMARY
- CVSS v4 5.1
- ATTENTION: Low attack complexity
- Vendor: Siemens
- Equipment: SIPROTEC 5
- Vulnerability: Cleartext Storage of Sensitive Information
2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker with physical access to read the sensitive information from the filesystem of the device.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Siemens reports the following products are affected:
- Siemens SIPROTEC 5 7SK85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SJ81 (CP100): vers:all/*
- Siemens SIPROTEC 5 7SL86 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SL86 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SJ86 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SK82 (CP100): vers:all/*
- Siemens SIPROTEC 5 6MD84 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SA87 (CP200): vers:all/*
- Siemens SIPROTEC 5 7ST85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SD87 (CP200): vers:all/*
- Siemens SIPROTEC 5 7UT87 (CP300): vers:all/*
- Siemens SIPROTEC 5 6MD89 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SD82 (CP100): vers:all/*
- Siemens SIPROTEC 5 6MD85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7ST86 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SJ82 (CP150): vers:all/*
- Siemens SIPROTEC 5 7UT86 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SX85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SD87 (CP300): vers:all/*
- Siemens SIPROTEC 5 7VU85 (CP300): vers:all/*
- Siemens SIPROTEC 5 6MU85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SD86 (CP300): vers:all/*
- Siemens SIPROTEC 5 7UT86 (CP300): vers:all/*
- Siemens SIPROTEC 5 7VK87 (CP200): vers:all/*
- Siemens SIPROTEC 5 7UT85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7UT82 (CP150): vers:all/*
- Siemens SIPROTEC 5 7SA87 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SJ81 (CP150): vers:all/*
- Siemens SIPROTEC 5 7SJ82 (CP100): vers:all/*
- Siemens SIPROTEC 5 7SA82 (CP100): vers:all/*
- Siemens SIPROTEC 5 7UT87 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SX82 (CP150): vers:all/*
- Siemens SIPROTEC 5 7SD86 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SL87 (CP300): vers:all/*
- Siemens SIPROTEC 5 6MD85 (CP200): vers:all/*
- Siemens SIPROTEC 5 7ST85 (CP200): vers:all/*
- Siemens SIPROTEC 5 Compact 7SX800 (CP050): vers:all/*
- Siemens SIPROTEC 5 6MD86 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SD82 (CP150): vers:all/*
- Siemens SIPROTEC 5 7KE85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SL82 (CP100): vers:all/*
- Siemens SIPROTEC 5 7SL82 (CP150): vers:all/*
- Siemens SIPROTEC 5 7VE85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7KE85 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SA86 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SL87 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SY82 (CP150): vers:all/*
- Siemens SIPROTEC 5 6MD86 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SJ86 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SA86 (CP300): vers:all/*
- Siemens SIPROTEC 5 7UM85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SS85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SK82 (CP150): vers:all/*
- Siemens SIPROTEC 5 7UT82 (CP100): vers:all/*
- Siemens SIPROTEC 5 7SS85 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SJ85 (CP200): vers:all/*
- Siemens SIPROTEC 5 7UT85 (CP200): vers:all/*
- Siemens SIPROTEC 5 7SK85 (CP200): vers:all/*
- Siemens SIPROTEC 5 7VK87 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SJ85 (CP300): vers:all/*
- Siemens SIPROTEC 5 7SA82 (CP150): vers:all/*
3.2 VULNERABILITY OVERVIEW
3.2.1 CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312
The affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device.
CVE-2024-53651 has been assigned to this vulnerability. A CVSS v3 base score of 4.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A CVSS v4 score has also been calculated for CVE-2024-53651. A base score of 5.1 has been calculated; the CVSS vector string is (CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER
Steffen Robertz, Stefan Viehböck, and Constantin Schieber-Knöbl from SEC Consult Vulnerability Lab reported this vulnerability to Siemens.
Siemens then reported this vulnerability to CISA.
4. MITIGATIONS
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Limit physical access to affected devices to trusted personnel.
- All affected products: Provision certificates signed by customer PKI as described in https://support.industry.siemens.com/cs/document/109768375.
- SIPROTEC 5 6MD85 (CP200), SIPROTEC 5 6MD86 (CP200), SIPROTEC 5 7KE85 (CP200), SIPROTEC 5 7SA86 (CP200), SIPROTEC 5 7SA87 (CP200), SIPROTEC 5 7SD86 (CP200), SIPROTEC 5 7SD87 (CP200), SIPROTEC 5 7SJ85 (CP200), SIPROTEC 5 7SJ86 (CP200), SIPROTEC 5 7SK85 (CP200), SIPROTEC 5 7SL86 (CP200), SIPROTEC 5 7SL87 (CP200), SIPROTEC 5 7SS85 (CP200), SIPROTEC 5 7ST85 (CP200), SIPROTEC 5 7UT85 (CP200), SIPROTEC 5 7UT86 (CP200), SIPROTEC 5 7UT87 (CP200), SIPROTEC 5 7VK87 (CP200): Currently no fix is planned.
- SIPROTEC 5 6MD84 (CP300), SIPROTEC 5 6MD85 (CP300), SIPROTEC 5 6MD86 (CP300), SIPROTEC 5 6MD89 (CP300), SIPROTEC 5 6MU85 (CP300), SIPROTEC 5 7KE85 (CP300), SIPROTEC 5 7SA82 (CP100), SIPROTEC 5 7SA82 (CP150), SIPROTEC 5 7SA86 (CP300), SIPROTEC 5 7SA87 (CP300), SIPROTEC 5 7SD82 (CP100), SIPROTEC 5 7SD82 (CP150), SIPROTEC 5 7SD86 (CP300), SIPROTEC 5 7SD87 (CP300), SIPROTEC 5 7SJ81 (CP100), SIPROTEC 5 7SJ81 (CP150), SIPROTEC 5 7SJ82 (CP100), SIPROTEC 5 7SJ82 (CP150), SIPROTEC 5 7SJ85 (CP300), SIPROTEC 5 7SJ86 (CP300), SIPROTEC 5 7SK82 (CP100), SIPROTEC 5 7SK82 (CP150), SIPROTEC 5 7SK85 (CP300), SIPROTEC 5 7SL82 (CP100), SIPROTEC 5 7SL82 (CP150), SIPROTEC 5 7SL86 (CP300), SIPROTEC 5 7SL87 (CP300), SIPROTEC 5 7SS85 (CP300), SIPROTEC 5 7ST85 (CP300), SIPROTEC 5 7ST86 (CP300), SIPROTEC 5 7SX82 (CP150), SIPROTEC 5 7SX85 (CP300), SIPROTEC 5 7SY82 (CP150), SIPROTEC 5 7UM85 (CP300), SIPROTEC 5 7UT82 (CP100), SIPROTEC 5 7UT82 (CP150), SIPROTEC 5 7UT85 (CP300), SIPROTEC 5 7UT86 (CP300), SIPROTEC 5 7UT87 (CP300), SIPROTEC 5 7VE85 (CP300), SIPROTEC 5 7VK87 (CP300), SIPROTEC 5 7VU85 (CP300), SIPROTEC 5 Compact 7SX800 (CP050): Currently no fix is available.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.
For more information see the associated Siemens security advisory SSA-111547 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.
5. UPDATE HISTORY
- February 13, 2025: Initial Publication